An industrial park power distribution system may need to supply multiple factories, warehouses, offices, workshops, utility buildings and future tenants from the same medium-voltage network. Unlike a single factory, the load mix can change continuously as new production lines and facilities are added.
TY Transformer provides power and distribution transformer solutions for industrial parks, manufacturing campuses and multi-building industrial facilities. Transformer configurations can be developed around incoming grid voltage, individual load zones, redundancy requirements and planned expansion.
Industrial parks may simultaneously supply motors, HVAC, compressors, production machinery, warehouses, offices, lighting, EV charging systems and power-electronic loads. Capacity planning should account for load diversity, maximum simultaneous demand and the expected profile of future tenants.
Instead of concentrating all capacity in a single transformer, larger industrial parks can use a main incoming transformer combined with multiple zoned distribution transformers. This makes future capacity expansion easier and can limit the effect of maintenance or faults to individual load areas.
Locating distribution transformers closer to major load centers can reduce low-voltage cable distances and associated distribution losses. High-efficiency transformers also reduce the continuous no-load and load losses accumulated across multiple units.
For industrial parks receiving 35kV utility power, TY's 35kV Oil Immersed Distribution Transformer provides capacities from 630kVA to 31,500kVA. The series uses CRGO core material and ONAN cooling and can be customized around project voltage and capacity requirements.
The Premium Efficiency Oil Type Distribution Transformer is available from 30kVA to 2500kVA for 6kV–11kV distribution systems. It is suitable for outdoor substations serving production zones, warehouses and individual industrial buildings.
Where transformers need to be installed inside factory buildings or electrical rooms, TY's 10kV Dry Type Epoxy Resin Cast Power Transformer offers an oil-free solution from 30kVA to 2500kVA. Protective enclosures, cooling arrangements and electrical parameters can be selected according to the project environment.
Utility incoming voltage: Define the grid connection and required secondary distribution voltages.
Existing load: Provide installed and maximum-demand loads for each building or production zone.
Future expansion: Reserve capacity for additional factories, equipment or tenants.
Load characteristics: Identify large motors, VFDs, UPS systems and other nonlinear loads.
Distribution architecture: Evaluate centralized versus zoned transformer arrangements.
Redundancy: Determine whether critical production areas require multiple transformers or alternative feeders.
Site environment: Confirm indoor/outdoor installation, ambient temperature, altitude and pollution conditions.
Industrial park projects rarely have identical electrical requirements. TY's engineering team can customize transformer capacity, voltage ratio, tap range, vector group, winding material, cooling arrangement, enclosure and accessories according to the project's electrical design.
For large parks, TY can assist in selecting different transformer types for different distribution levels rather than applying one transformer specification throughout the entire site.
Shijiazhuang Tianya Electric has specialized in transformer and power distribution equipment since 2007. Today, the company operates a 20,000㎡ production base supported by more than 30 technical specialists and an integrated manufacturing system.
Transformer cores and electromagnetic wire are produced in-house. Production covers core processing, winding, vacuum processing, assembly, testing, packaging and delivery, allowing critical manufacturing stages to be controlled throughout the project.
TY maintains ISO 9001, ISO 14001 and ISO 45001 management systems. Depending on product and project requirements, testing covers winding resistance, transformer ratio, vector group, no-load loss and current, load loss and impedance, insulation resistance, dielectric performance and sealing tests.
Send us your single-line diagram, incoming voltage, building-by-building load schedule, required capacities, frequency, installation locations, redundancy requirements and expansion plan. TY Transformer can recommend an appropriate combination of main and distribution transformers for your industrial park.
Contact TY Transformer for an industrial park power distribution proposal and quotation.
Voltage Transformer for Industrial Park helps developers and utility contractors design power infrastructure that can support current tenants and future expansion. Because industrial parks often include mixed loads from different industries, transformer planning must consider capacity reserve, feeder layout, maintenance access, and reliability. Voltage Transformer for Industrial Park gives buyers a flexible solution for phased construction, tenant connection, load growth, and long-term electricity distribution across manufacturing clusters and logistics facilities.
Contact us